BWP pays to replace gas
$1,000 per ton, up to $2,500 for standard customers ($5,000 for income-qualified residents), on a central or mini-split heat pump. Each unit must replace an existing natural gas appliance.
Local guide · independent publisher, not a contractor
Burbank has its own utility, so the rebate that matters is Burbank Water and Power's: $1,000 per ton, up to $2,500, for a heat pump that replaces gas equipment. Burbank also issues its own permits, and its airport averages 53.9 days a year at 90 °F or above.
Reviewed · 5 named sources · No named reviewer yet; see our editorial policy.
$1,000 per ton, up to $2,500 for standard customers ($5,000 for income-qualified residents), on a central or mini-split heat pump. Each unit must replace an existing natural gas appliance.
BWP asks for proof the job passed inspection by Burbank's Building and Safety Division and a copy of the finaled permit. An unpermitted install gets nothing.
Burbank, not LADBS, issues mechanical permits. The city portal takes simple mechanical permits online.
| Heat pump size | $1,000 × tons | Paid (standard cap $2,500) |
|---|---|---|
| 2 tons | $2,000 | $2,000 |
| 2.5 tons | $2,500 | $2,500 |
| 3 tons | $3,000 | $2,500 |
| 4 tons | $4,000 | $2,500 |
Our arithmetic from the BWP form's per-ton amount and cap. Income-qualified residents have a $5,000 cap. A $750 panel incentive can be added to a heat pump rebate, not claimed alone.
The condition that decides it
The heat pump has to replace gas equipment, usually a gas furnace. Swapping an old AC for a new AC, or adding a heat pump while keeping the furnace, does not fit the rule as the form states it.
Burbank sits in the eastern San Fernando Valley, and NOAA's station is at the airport itself. It averages 53.9 days a year at 90 °F or above, roughly eleven times LAX, and 7.2 days at 100 °F.
Days a year at 90 °F or above
| Station | Days ≥90 °F | Days ≥100 °F | Avg summer high | Cooling degree days |
|---|---|---|---|---|
| LAX airport USW00023174 | 4.8 | 0.2 | 74.6 °F | 720 |
| Downtown LA (USC) USW00093134 | 25.6 | 1.8 | 81 °F | 1,296 |
| Burbank–Glendale–Pasadena airport USW00023152 | 53.9 | 7.2 | 85.3 °F | 1,481 |
| Pasadena USC00046719 | 74.1 | 9.5 | 88 °F | 1,604 |
| Woodland Hills (Pierce College) USC00049785 | 115.3 | 35.6 | 93.7 °F | 1,819 |
Sizing note
Burbank needs more capacity than the coast but less than the west Valley. A Manual J load calculation sets the size. Burbank is in CEC climate zone 9 (verify the address with the CEC tool).
Burbank's housing boomed in the 1940s: 23% of homes date from that decade, more than any other, and the median year built is 1961. Post-war houses often have a gas furnace and ducts in the attic or crawlspace, which makes a ducted heat pump the common upgrade, and the BWP rebate fits that swap.
Burbank homes by decade built
Expect the ducts on a 1940s house to need sealing to pass the Title 24 leakage test; LA sources publish duct repair at $800–$4,500.
| House | Usual fit | BWP rebate? |
|---|---|---|
| Gas furnace with ducts | Ducted heat pump replacing the furnace | Yes, $1,000/ton to the cap |
| Gas wall heater, no ducts | Mini-split heat pump replacing the wall heater | Yes, if it replaces the gas heater |
| Old AC, furnace stays | Central AC | No |
| Hillside home in a fire zone | Any of the above, with better filtration | As above |
Burbank AC and heat pump prices are not published reliably, so the figures below are the Los Angeles published ranges from 6 named LA sources, not Burbank quotes.
| Job | Published LA range, 2026 |
|---|---|
| Central AC, 3 tons, existing ducts | $8,000–$16,000 |
| Ducted heat pump, 2 / 3 tons | $9,000–$11,500 / $12,000–$15,000 |
| Mini-split, 1 / 2 zones | $4,000–$7,500 / $9,000–$12,500 |
| Panel upgrade (adder) | +$2,000–$7,500 |
Sources and dates: AC installation cost in Los Angeles. The federal 25C credit applied to qualifying equipment placed in service before 31 December 2025. A system installed in 2026 does not qualify.
Compare quotes in the quote comparison tool.
Use the Los Angeles published ranges, because no reliable Burbank-only figure exists: a 3-ton central AC at $8,000–$16,000 and a 3-ton ducted heat pump at $12,000–$15,000. Cost pages that quote a few thousand dollars usually leave out permits, tests and ducts, and one widely cited "Burbank" range is for Burbank, Illinois.
BWP pays $1,000 per ton on a central heat pump or mini-split heat pump, capped at $2,500 for standard customers and $5,000 for income-qualified residents. Each unit must replace an existing natural gas appliance.
No. It is an electrification rebate: it pays for a heat pump that replaces gas equipment, such as a gas furnace. A cooling-only AC does not qualify.
BWP lists a $750 panel incentive that can be added to a heat pump rebate but cannot be claimed on its own.
Proof the installation passed inspection by Burbank's Building and Safety Division and a copy of the finaled permit, with the application form.
The City of Burbank Building and Safety Division, not LADBS. The city portal takes simple mechanical permits online.
NOAA's Burbank airport station averages 53.9 days a year at 90 °F or above and 7.2 at 100 °F, with an 85.3 °F average summer high. LAX averages 4.8 days at 90 °F.
Parts of the Verdugo Mountain foothills are mapped as fire hazard severity zones. Check your address on CAL FIRE's map, and ask the contractor about filtration and where the outdoor unit can sit.
It is worth pricing. A heat pump replaces both AC and furnace, and the BWP rebate only pays when gas equipment is replaced. On a 2-ton heat pump the rebate ($2,000) is a large share of the published $9,000–$11,500 range.