Since 1 January 2025, new residential AC and heat pump equipment made or imported for the US must use a refrigerant with a global warming potential of 700 or less, which in practice means A2L refrigerants such as R-454B or R-32. California's own rule, from CARB, bars refrigerants of GWP 750 or more in new AC equipment from the same date. EPA sets no installation deadline for split systems whose components were all made before 2025, so some R-410A stock can still go in.

Reviewed · 6 named sources · No named reviewer yet; see our editorial policy.

The federal rule in one table

EPA Technology Transitions limits for AC and heat pumps
WhatLimitDate
New residential and light commercial AC and heat pump products (manufacture and import)GWP 7001 January 2025
New field-assembled residential split systems (installation)GWP 7001 January 2025, with no installation date for systems whose specified components were all made or imported before 2025
Variable refrigerant flow systemsGWP 7001 January 2027

EPA Technology Transitions restrictions table, read 2026-10-20. EPA notes the table is informational; 40 CFR Part 84, Subpart B governs.

California has its own limit

CARB regulates HFCs separately under state law. Its air-conditioning rule says new residential and non-residential AC equipment "must use refrigerants with a GWP less than 750", effective 1 January 2025 for most systems, including ducted central ACs and heat pumps. Window and room units, portables and PTACs had to comply from 1 January 2023; VRF systems from 1 January 2026.

R-410A is well over both limits. R-454B and R-32 come in under both, which is why nearly every new split system offered in Los Angeles uses one of them. CARB also has its own provisions on equipment made before the deadline, so where a quote offers old R-410A stock, ask the contractor to confirm in writing that it can be installed in California.

CARB, SNAP air-conditioning equipment, read 2026-10-26.

What "A2L" means

A2L is a safety class: lower toxicity, lower flammability. R-410A was non-flammable. R-454B and R-32 can burn under the right concentration, which changes how equipment is built and installed. Installers need A2L-rated recovery machines and vacuum pumps, plus training on the new rules for brazing and leak checks.

What it means for you

You never handle refrigerant. What you need is a contractor who installs A2L systems routinely and a quote that names the refrigerant.

The leak sensor in your new indoor unit

Many A2L indoor units ship with a refrigerant detection system (RDS): a sensor, usually low near the coil, wired to the unit's controls. UL describes what it does. When the sensor reads refrigerant at 25 percent of the lower flammability limit, the system must start mitigation within 15 seconds, typically by turning on the indoor fan to dilute the leak and shutting off the compressor, and it holds that response for at least five minutes.

Whether your unit needs a sensor depends on its charge and installation instructions, under the UL 60335-2-40 equipment standard. In practice that means three things for an LA job:

  • The installer follows the manufacturer's sensor placement, which can change when an air handler is mounted horizontally in an attic or crawlspace.
  • Sensor wiring and any connections to zoning dampers or alarms are part of the job, not an extra.
  • A fan that suddenly runs on its own may be the RDS doing its job. Call the installer instead of unplugging it.

UL Solutions, inspecting refrigerant detection systems, read 2026-10-26.

Coils, line sets and what can be reused

A new A2L condenser cannot be paired with an existing R-410A coil. The outdoor and indoor sections are rated, certified and charged as one matched system, and the AHRI rating that rebates depend on belongs to that pair. Expect the coil (or the whole air handler) to be replaced along with the outdoor unit.

The copper line set is different. Many manufacturers allow an existing line set to be reused if it is the right size, clean and passes a pressure and vacuum test. Each manufacturer sets its own conditions, so the answer belongs in the installation instructions, not in a sales pitch. Ask which way the quote goes, because a new line set through finished walls or a long attic run is real money: published LA prices put a line set at $300–$1,500.

Should you buy leftover R-410A equipment?

New equipment uses lower-GWP A2L refrigerants such as R-454B or R-32. An EPA rule effective 27 July 2026 lets installers keep fitting R-410A split systems built before 2025 until stock runs out. California sets its own HFC rules through CARB, so ask which refrigerant the quote uses and whether it can be installed here.

Leftover R-410A system

  • Legal to install if every component predates 2025
  • Future service depends on R-410A supply
  • Coil and condenser must both be old stock
  • Ask for written confirmation it meets California rules

New A2L system

  • Current production and current ratings
  • Needs an A2L-trained installer and, often, a leak sensor
  • Cannot be mixed with an old R-410A coil

Repairing an existing R-410A system

EPA's restrictions apply to new systems. Components used to repair existing systems are not restricted (EPA table, note 5), so an older system can still be repaired and recharged with R-410A. The question is whether it is worth it: see repair vs replacement.

Does A2L cost more?

We found no published Los Angeles figure that separates an A2L premium from the rest of an installation price, so we print none. The published LA ranges for a full replacement are on the AC replacement cost guide. Ask each bidder whether the price is for A2L or old-stock equipment, so you compare like with like.

Questions for the quote

  • Which refrigerant does the system use?
  • Is it current production or pre-2025 stock, and does that cover both coil and condenser?
  • Are your technicians trained and equipped for A2L?
  • Does the indoor unit need a leak detection sensor, and is its wiring included?
  • Is the existing line set being reused, and how will it be tested?

Sources

Questions

Is R-410A banned in 2026?

New equipment made or imported since 1 January 2025 cannot use it. Split systems whose components were all made before 2025 can still be installed under the federal rule, and existing systems can still be repaired.

What refrigerant do new ACs use?

Mostly A2L refrigerants such as R-454B and R-32, which meet both EPA's 700 GWP limit and CARB's under-750 limit.

Can I put a new R-454B condenser on my old coil?

No. The condenser and coil must be a matched system designed for the same refrigerant.

Are A2L refrigerants safe at home?

They are classed as lower toxicity and lower flammability. Equipment is built to the UL 60335-2-40 standard for that class, and many indoor units carry a leak sensor that runs the fan and stops the compressor if refrigerant builds up.

Why does my new air handler fan come on by itself?

On an A2L system it may be the refrigerant detection system responding to a reading. Leave it powered and call the installer.

Can my old line set be reused?

Often, if it is the right size and passes the manufacturer's tests. The installation instructions decide, so ask the contractor which applies.

Next step

Free quote request

Get a quote to check against these numbers

  1. Tell us about the job. Service, ZIP, property and timing. The form says right away if your ZIP is outside the area.
  2. We check the license first. Requests go only to contractors whose CSLB C-20 license we have matched on the state register. If none covers your ZIP yet, we email you and say so.
  3. Compare what comes back. Line the written quote up against the published ranges and the quote checklist.

No cost and no obligation. We are a publisher, not a contractor; contractors pay us for introductions. How that works.

Request AC installation quotes

Licensed Los Angeles HVAC contractors. Free, no obligation.

Enter a Los Angeles-area ZIP (900xx–918xx). Orange County, Ventura County and Santa Clarita have no partner yet.
Please add your name.
A phone number is how the contractor reaches you.
Please add a working email.
Please add the street address for the job.
Get installation quotes